Type |
Gutor PXP 1000 (single phase) |
Gutor PXP 3000 (three phase) |
Ratings |
5,10, 15, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160 kVA(Higher ratings upon request) |
Operating temperature |
- 10 to +40 °C (max. 55 °C on request) |
Allowable air humidity |
< 95 % (non condensing) |
Noise level |
55 – 65 dBA (depending on rating) |
Communication protocols |
Modbus RTU (4-Wire), Modbus TCP, Webpage (HTTP), SNMP, IEC 61850 |
Altitude above sea level |
< 1000 m without load de-rating |
Input |
Rectifier |
PFC technology (less than 5 % distortion back to line power) |
Voltage |
3 x 380 / 400 / 415V (other voltages on request) |
Voltage tolerance |
''+/- 10% for DC in tolerance -15/+10% for function |
Battery circuit |
Nominal voltage |
400VDC |
Applicable batteries |
Lead Acid, Nickel Cadmium |
Output |
Voltage |
220 / 230 / 240V (others on request) |
380 / 400 / 415V (others on request) |
Tolerance (static) |
+/- 1 % |
Frequency stability (free running) |
< 0.01 % |
Efficiency |
up to 91% depending on type |
Distortion |
linear load: ≤ 3 % / non-linear load: ≤ 5 % |
Overload inverter |
200% / 50-100 ms, 150% / 1 min, 125% /10 min |
Overload bypass |
1000 % / 100 ms, 150 % / 1 min, 125 % / 10 min |
Benefits
Reliability
Platform with large installation base and many years of proven field reliability. Decentralized control architecture for increased reliability. Redundant and individually monitored fans.
Small Footprint
Smallest footprint on the market among industrial UPS systems. Ideal for applications with limited available space.
Low THDi
PFC rectifier dramatically reduces input harmonics (< 5 %THDi), minimizing distortion to upstream equipment.
Transformerless option
Optional transformerless configuration available. Further reduction in footprint, weight, and cost while increasing efficiency and having equivalent performance.<section style="box-sizing: border-box; padding-bottom: 2em; line-height: 1.5em; border-bottom: 1px solid rgb(231, 230, 230); padding-top: 2em; color: rgb(98, 100, 105); font-family: " arial="" rounded",="" "lucida="" grande",="" lucida,="" sans="" unicode",="" sans-serif;="" font-size:="" 13px;="" background-color:="" rgb(250,="" 250,="" 250);"="">
Applications
- Oil & Gas, Petrochemical (onshore, offshore, pipelines, refining, FPSO)
- Power generation, including transmission and distribution
- Mining
- Water treatment including desalination
- Transport
- Chemical industry
- Other industrial applications
具有PFC整流器的双变换UPS系统
市场的第一个真正的工业交流UPS与PFC整流器
技术信息
Gutor PXP 1000(单相)Gutor PXP 3000(三相)
评级5,10,15, 20, 30,40, 50, 60,80, 100, 120,140, 160千伏安(要求较高的评级)
操作温度- 10至+40°C(最大55°C的要求)
允许空气湿度<95%(不凝结)
噪音等级55~65 dBA(视等级而定)
通信协议Modbus RTU(4线)、Modbus TCP、网页(HTTP)、SNMP、IEC 61850
海平面海拔1000米无负荷降级
输入
整流器PFC技术(失真小于5%线功率)
电压3×380/400/415V(其他电压按要求)
公差中的DC电压公差“+/- 10%”
-函数的15/10%
电池电路
额定电压400伏直流
适用蓄电池铅酸镉镍
产量
电压220/230 /240V(其他要求)380/400 / 415V(其他请求)
公差(静态)+/- 1%
频率稳定度
(自由奔跑)< 0.01%
效率高达91%取决于类型
畸变线性负载:3%Ω/非线性负载:5%
过载逆变器200%/50-100ms,150%/1分钟,125%/10分钟
过载旁路1000%/100毫秒,150%/1分钟,125%/10分钟
特征
具有PFC整流器的工业交流UPS
具有PFC整流器(功率因数校正)的Gutor PXP将极大地降低THDI(在输入处的谐波)到非常低的电平。因此,对于上游网络较少失真的应用是正确的选择。
它的稳健设计,也符合石油和天然气等重工业所面临的恶劣环境的要求。
订购PXP无变压器的可能性将进一步减少已经非常小的占地面积。
效益
可靠性
平台安装基础大,具有多年的现场可靠性。分散控制结构,提高可靠性。冗余和单独监控的风扇。
小足迹
工业UPS系统市场上的最小占地面积。适用于有限的可用空间。
低THDI
PFC整流器显著降低输入谐波(<5% THDI),使上游设备的失真最小化。
无变压器选项
可选的无变压器配置可用。进一步减少占地面积、重量和成本,同时提高效率和具有同等的性能。
应用
石油和天然气、石化(陆上、海上、管道、炼油、FPSO)
-发电,包括输电和配电
开采
水处理包括海水淡化
-运输
化学工业 及其他行业